cerasonar 6280 — Closed backbox with a wood-based cover panel and documents attached.
cerasonar 4080 — Closed backbox with a wood-based cover panel.
cerasonar 4062 — Closed backbox with a wood-based cover panel.
Corner of the closed backbox with a dark side wall and exposed wooden edge.
cerasonar 6280 — Angled view of the open backbox with profiled foam and two crossbars.
cerasonar 4080 — Long, narrow backbox with white acoustic foam, seen at an angle.
cerasonar 4062 — Angled view of the open backbox with white acoustic foam and cable entry.
cerasonar 6280 — Front view of the open backbox with two crossbars over the acoustic foam.
cerasonar 4080 — Front view of the open backbox with its long, foam-lined interior.
cerasonar 4062 architect — Rear view of the installation frame with the cerasonar wordmark.
cerasonar 2525 fit — Milled mounting plate with the two rear exciters in view.
cerasonar 4062 architect — Installation frame with a light-coloured front plate secured by screws.
cerasonar 4062 — Front view of the open backbox with profiled acoustic foam.

cerasonar installation frames (backboxes)

1291

Regular price€208,95
/

installation frame

Installation Frame (Backbox) – Engineered as Part of the Complete System

The cerasonar installation frame (backbox) is far more than a mounting solution. Developed as an integral part of the complete cerasonar system, it provides a defined acoustic environment for the loudspeaker or subwoofer, ensuring predictable performance, simplified installation and consistent sound quality across different construction methods.

Constructed from waterproof plywood and supplied with integrated BasotectĀ® acoustic insulation, the installation frame (backbox) effectively reduces rear sound radiation while providing a stable and durable mounting platform. The defined internal volume allows the loudspeaker or subwoofer to perform as intended, independent of the surrounding wall or ceiling construction.

Thanks to its versatile design, the installation frame (backbox) can be used in a wide variety of installation scenarios, including in-situ concrete, masonry, timber construction and drywall ceilings. Optional vibration dampers further minimise structure-borne sound transmission, making the system particularly suitable for suspended plasterboard ceilings and other vibration-sensitive constructions.

Every installation frame (backbox) is supplied ready for installation with pre-drilled fixing points, OBO cable glands with integrated strain relief, BasotectĀ® acoustic insulation, an OSB protection panel and alignment battens. This reduces installation time while ensuring a clean, reliable and repeatable installation process.

To support different construction methods, cerasonar offers a range of dedicated installation accessories. The drywall ceiling kit enables fast and precise installation in plasterboard ceilings, while the drywall ceiling anti-vibration kit incorporates vibration dampers to significantly reduce structure-borne sound in suspended ceiling constructions.

For solid walls, the masonry installation kit provides all required mounting hardware together with a fast-curing two-component construction foam for secure installation.

For bespoke interior applications, the panel pocket mount kit has been developed for wood, veneer, HPL, MDF and furniture panel constructions. Using a CNC-machined rear pocket, the loudspeaker can be integrated completely invisibly while maintaining the visible surface finish. The dedicated pocket mount double-sided tape simplifies positioning and initial fixation of the loudspeaker before the rear mounting bracket is installed.

As with every cerasonar component, the installation frame (backbox) has been engineered to work hand in hand with the loudspeaker, DSP amplifier and factory DSP preset. Together, they form a complete system that delivers predictable acoustic performance from planning through to final commissioning.

sizes and information for:
- 4062 architect

  • Only for drywall - very shallow only 5 cm incl. speaker!
  • Use cerasonar DSP settings with correct preset for best sound quality!
  • Plasterboard can be screwed all round the front plate of the housing (screw length no more than 25 mm)
  • Dimensions: 55,5 x 77,5 x 3,7 cm
    (4,9 cm incl. OSB plate)
  • Weight: X,X kg

sizes for:
- 1520 & 2525 fit
- 4062 reference (pro)

  • Installation cut out: 42 x 64 x 14 cm
  • Dimensions: 40,0 x 62,0 x 12,0 cm
    (13,2 cm incl. OSB plate or CNC milled installation plate for 1520 & 2525 fit)
  • Weight: 4,8 kg

sizes for:
- 6062 reference (pro)
- 6062 sub

  • Installation cut out: 62 x 64 x 14 cm
  • Dimensions: 60,0 x 62,0 x 12,0 cm
    (13,2 cm incl. OSB blank plate)
  • Weight: 7,1 kg

sizes for:
- 4080 ultimate

  • Installation cut out: 42 x 82 x 14 cm
  • Dimensions: 40,0 x 80,0 x 12,0 cm
    (13,2 cm incl. OSB blank plate)
  • Weight: 6,1 kg

sizes for:
- 10040 sub

  • Installation cut out: 42 x 102 x 14 cm
  • Dimensions: 40,0 x 100,0 x 12,0 cm
    (13,2 cm incl. OSB blank plate)
  • Weight: 7,7 kg

sizes for:
- 13362 sub

  • Installation cut out: 135,5 x 64 x 16,5 cm
  • Dimensions: 133,5 x 62 x 14,5 cm
    (15,7 cm incl. OSB blank plate)
  • Weight: X,X kg

DOWNLOAD the latest datasheet for the cerasonar installation frame (backbox) (PDF). Includes model compatibility, enclosure dimensions, OSB protection panel details and rear installation clearance information.

DOWNLOAD the architectural specification for the cerasonar installation frame (backbox) (PDF, nine languages). Use the tender text to define the loudspeaker model, backbox variant, construction and installation scope.

IN-SITU CONCRETE INSTALLATION

Rectangular opening in a concrete ceiling with a wood-based panel visible inside.

delivery content of cerasonar frame:
o Sturdy & waterproof glued "trailer" plywood housing
o High quality BasotectĀ® damping material
o Cable gland with integrated strain relief
o OSB blind panel & alignment battens
o Frame comes with pre-drilled holes for easy & fast installation

In-Situ Concrete Installation:
Dismantle the OSB blind panel, enlarge the cable pre-drill hole with a 16 mm drill, remove the separating film from the damping material and glue it into the installation frame, insert the OBO cable gland and tighten the nut.

Concrete is poured over the exposed steel reinforcement for a floor slab.

Then insert the loudspeaker cable.
Place the installation frame with the reassembled OSB blind panel in the desired position on the formwork and secure it. After concreting, remove the OSB blind panel. The loudspeaker can now be installed.


TIP:
If not only the joints are to be sealed and more than 2 mm levelling compound is to be applied to the in-situ concrete ceiling, fit a thinner OSB blind panel, e.g. 9 mm, so that the maximum application thickness on the speaker of 2 mm is not exceeded.

Cable entry hole in the side wall of a cerasonar backbox.

Always use a scrap piece of wood as a base when drilling to prevent the drill edge from fraying.

The white loudspeaker cable passes through a cable gland into the foam-lined backbox.

Secure the OBO cable gland with the supplied nut, feed the loudspeaker cable through and secure the cable against pulling by screwing the outer black plastic cover.

Wood-based panel set flush with the concrete ceiling at the planned loudspeaker position.

After removing the formwork, remove the OSB blind panel. The loudspeaker can then be installed.

Mounting hardware for masonry installation in the corner of an open cerasonar backbox.

Easy and neat to use

masonry installation kit

delivery content:

  • Masonry installation set consisting of:
    - Frame dowels with countersunk Torx screws (8x100 mm)
    - Ponal PNR10 (fast-curing, 2-component construction foam) (or similar)
check out the masonry installation kit
A bricklayer spreads mortar on a course of red bricks.

Masonry installation:

Create a sufficiently dimensioned niche in the masonry, leaving enough space all round, including for the syringe of the construction foam.
Install the cable gland and damping material as described above and then refit the OSB blind panel. Screw the alignment battens to the OSB blind panel.
Now align the installation frame in the centre of the niche and fit the alignment slats to the wall.
Fill the surrounding slot with sufficient construction foam and remove the alignment slats and OSB blind panel once dry. If necessary, fit frame dowels for reinforcement. The loudspeaker can now be installed.

TIP:
If a very deep niche is available, the rear volume can be used to increase the bass reproduction. To do this, drill a hole in the rear wall of the installation frame using a large circular drill.

An open cerasonar backbox with white acoustic foam and mounting rails alongside.

EASY CEILING INSTALLATION

drywall ceiling kit

delivery content:

  • Drywall installation set consisting of:
    - Installation battens
    - Drive-in nuts
    - Screws
check out the drywall ceiling kit
A hand holds a screwdriver against the inside of the foam-lined cerasonar installation frame.

EASY CEILING INSTALLATION

Make a sufficiently dimensioned cut-out in the plasterboard (1-2 mm larger than the speaker), mount the long installation battens with the enclosed metric screws. Ensure that the battens are flush with the rest of the frame. Insert the installation frame into the opening at an angle.
Install the cable gland and damping material, see above.
Then fit the two short installation battens by carefully moving the installation frame in the ceiling.
Now align the housing in the centre of the opening. The screws are screwed through the plasterboard into the installation battens, one screw every 10 cm.

A metal bracket with a vibration isolator is screwed to the side of a cerasonar backbox.

Structure-borne noise reduction

drywall ceiling anti-vibration kit

delivery content:

  • Ceiling & vibration installation set consisting of:
    - Installation battens
    - Drive-in nuts
    - Screws
    - Pre-assembled dampers
check out drywall ceiling anti-vibration kit
cerasonar anti-vibration kit — Metal bracket with vibration isolators, screws and tee nuts.
rubber buffers effectively reduce structure-borne noise

Vibration damper installation

Four M8 threaded rods are mounted on the ceiling. The installation height of the installation frame must then be determined. Use M8 nuts to create a limit stop and then insert the installation frame, readjust if necessary and screw in place (be sure to use screw locking!). Then fit the installation battens and screw the plasterboard to the installation battens.

Attention: Delivery without M8 threaded rods and dowels. Only suitable for ceiling installation!